Different density measurement results between V15 and V16

Different density measurement results between V15 and V16

Problem/Question
When comparing density measurements between Ergosoft RIP 15 and Ergosoft 16, differences may occur. This is due to the newly added density specifications for the primary inks.

Solution/Work-Around
To change back to the default setting of Ergosoft RIP 15 please follow the step below:
  1. Open the "Application Defaults" under "Tools" in the menue bar
  2. Select "Spectrophotometer" in "Application" tab
  3. Set in the "Measurement Standards" field the "Density specification for primary inks:" from "Status E - ISO 5-3 (Default)" to "DIN 16536-2 (Legacy)"

Related Articles & Links

    • Related Articles

    • Calibration & Profile with White Ink as “User modified curve”

      Problem/Question “How to do a Calibration & Profiling with White Ink underlay, using a User modified curve" Solution/Work-Around In order to do a Calibration & Profile with the White Ink underlay, there is a need to define how we want to manage the ...
    • How to exclude spot colors from Density Linearization

      Problem/Question You are using e.g. spot colors that your spectrophotometer cannot read correctly so that you would like to not linearize them. Or you have almost identical printers, one running with e.g. CMYK only and the other running with CMYK ...
    • Calibration & Profile with White Ink using “Legacy modes"

      Problem/Question “How to do a Calibration & Profiling with White Ink underlay, using Legacy Modes" Solution/Work-Around In order to do a Calibration & Profile with the White Ink underlay, there is a need to define how we want to manage the white ...
    • 0x1203 Error: Command failed: S1 when measuring with Barbieri Spectro LFP

      Problem/Question When attempting to measure and/or do the White calibration with the Barbieri Spectro LFP, the measuring head does not move and it gives out the error message "0x1203 Error: Command failed: S1". Solution/Work-Around This issue usually ...
    • Deterioration in print quality after an ink changeover

      Problem/Question A deterioration in print quality is detected after an ink changeover. How can the print quality be restored? Solution/Work-Around Copy the PrintEnvironment used before the ink changeover and name it differently. Remove the embedded ...